The standard puncture device for safety shoes is a special instrument for testing the static pressure resistance and puncture performance of safety shoes. Here is a detailed description of the device:
First, the main use
The safety shoe standard puncture device is mainly used to test the static pressure resistance and puncture performance of the safety shoe under specific conditions to ensure that the safety shoe can effectively protect the safety of the wearer's foot during use.
Second, instrument characteristics
Electric lift drop: The upper plate (static pressure) and test nail (puncture) are electrically lifted and dropped to automate the test process.
High precision pressure sensor: The lower plate is connected to a high precision dedicated pressure sensor for accurate measurement of static pressure and force values during puncture.
LED digital display: Test results are visually displayed through the LED digital display, which is easy to read and record.
Third, the main technical indicators
Upper and lower plate spacing: up to 280mm, in order to adapt to different specifications of safety shoes testing needs.
Measuring force range: 0 ~ 20000N, covering a wide range of force values to ensure the accuracy and reliability of the test.
Force measurement accuracy: up to 1%, providing high precision test results.
Working power supply: AC220V, 50Hz, in line with conventional power supply standards, easy to access and use.
Fourth, applicable standards
The safety shoe standard piercing device is applicable to the national standard "GB/T 20991-2007 Test method for Personal protective equipment shoes" and other relevant international standards and industry standards. These standards specify the test methods, performance indicators and test requirements for safety shoes to ensure the accuracy and comparability of test results.
Fifth, use precautions
Before use, ensure that the test instrument is in good condition and carry out the necessary calibration and inspection.
During the testing process, the standard requirements and operating procedures should be followed to ensure the accuracy and reliability of the test results.
After the test, the test instrument and test site should be cleaned in time to keep the instrument clean and dry.
Regular maintenance and maintenance of the test instrument to extend its service life and maintain its stable performance.
To sum up, the standard puncture device for safety shoes is an important test equipment, which is of great significance for ensuring the quality and performance of safety shoes. In the process of use, relevant standards and operating procedures should be strictly observed to ensure the accuracy and reliability of test results.